About |
---|
LEXAN™ BFL2000U™是一种无定形的聚碳酸酯树脂。提供高度稳定的机械、电气、光学和热性能。是一种非氯化、非溴化阻燃剂,具有UL – 94 V0阻燃等级。耐冲击性好、尺寸稳定性好、清晰度好。采用注塑成型,适用于高反射率应用,具有耐候性。 |
Product Description | |
---|---|
Supplier | SABIC |
Generic | Polycarbonate |
Material Status | Commercial: Active |
Features | Weather resistance is good,Good Dimensional Stability,Halogen free |
Availabilitys | North America |
Technical Data | |||
---|---|---|---|
MECHANICAL | Nominal value | Unit | Test method |
tensile strength | |||
Yield, 50 mm/min | 60 | MPa | ISO 527 |
Fracture, 50 mm/min | 52 | MPa | ISO 527 |
Tensile strain | |||
Yield, 50 mm/min | 5 | % | ISO 527 |
Fracture, 50 mm/min | 70 | % | ISO 527 |
Tensile modulus | |||
1 mm/min | 2350 | MPa | ISO 527 |
bending strength | |||
Yield, 2 mm/min | 90 | MPa | ISO 178 |
Bending modulus | |||
2 mm/mim | 2300 | MPa | ISO 178 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | |||
23℃ | 630 | J/m | ASTM D256 |
-30℃ | 200 | J/m | ASTM D256 |
Total energy of instrument impact | |||
23℃ | 560 | cm-kgf | ASTM D 3763 |
Notched impact strength of cantilever beam | |||
23℃,80*10*3 | NB | kJ/m² | ISO 180/1U |
-30℃,80*10*3 | NB | kJ/m² | ISO 180/1U |
Impact strength of cantilever beam notch | |||
23℃,80*10*3 | 11 | kJ/m² | ISO 180-1A |
-30℃,80*10*3 | 10 | kJ/m² | ISO 180-1A |
Charpy Unnotch Impact strength | |||
23℃,80*10*3 | NB | kJ/m² | ISO 179/1eU |
-30℃,80*10*3 | NB | kJ/m² | ISO 179/1eU |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Vicat Softening Temp | 138 | ℃ | ASTM D1525 |
Hot deformation temperature | |||
0.45 MPa, 64 mm span | 132 | ℃ | ISO 75/Af |
1.8 MPa, 64 mm span | 120 | ℃ | ISO 75/Bf |
Unannealed, 3.2 mm | |||
Linear coefficient of thermal expansion | |||
MD:23~80℃ | 7.E-0.5 | 1/℃ | ISO 11359-2 |
TD:23:80℃ | 7.E-0.5 | 1/℃ | ISO 11359-2 |
Ball pressure test | |||
125℃±2℃ | pass | IEC 60695-10-2 | |
0.45MPa | 132 | ℃ | ASTM D 648 |
Vicat Softening Temp | |||
1.8MPa | 120 | ℃ | ASTM D 648 |
B50 | 139 | ℃ | ISO 306 |
B120 | 141 | ℃ | ISO 306 |
Relative temperature index | |||
Electrical performance | 80 | ℃ | UL 746B |
Impact mechanical performance | 80 | ℃ | UL 746B |
Non mechanical impact performance | 80 | ℃ | UL 746B |
PHYSICAL | Nominal value | Unit | Test method |
---|---|---|---|
Density | 1.29 | ASTM D792 | |
Shrinkage rate | |||
MD:3.2 mm | 0.5 – 0.7 | % | Internal Method |
Melt Flow Rate | |||
300℃,1.20kg | 26 | g/10min | ASTM D1238 |
Density | 1.29 | g/cm³ | ISO 1183 |
Water absorption rate | |||
24hr | 0.35 | % | ASTM D570 |
Saturation, 23 ℃ | 0.35 | % | ISO 62 |
23℃,50% RH | 0.15 | % | ISO 62 |
Melt Volume Rate | |||
300℃,1.2 kg | 24 | cm³/10min | ISO 1133 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Compared to the leakage tracing index | 2 | PLC Code | UL 746A |
Compared to the leakage tracing index | 350 | V | IEC 60112 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | |||
0.75 mm | V-2 | UL 94 | |
1.50 mm | V-0 | UL 94 |
Process Conditions | |||
---|---|---|---|
injection molding | Nominal value | Unit | Test method |
Drying temperature | 120 | °C | |
Drying time | 3 – 4 | hrs | |
Drying time (cumulative) | 48 | hrs | |
Maximum water content | 0.02 | % | |
Melt temperature | 270 – 295 | °C | |
Nozzle temperature | 265 – 290 | °C | |
Front Section Zone 3 Temperature | 270 – 295 | °C | |
Temperature in Zone 2 of the middle section | 260 – 280 | °C | |
Temperature in Zone 1 of the rear section | 250 – 270 | °C | |
Mold temperature | 70 – 95 | °C | |
Back pressure | 0.3 – 0.7 | MPa | |
Screw speed | 40 – 70 | rpm | |
Shoot to cylinder size | 40 – 60 | % | |
Depth of exhaust groove | 0.025 – 0.076 | mm |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |