Synres-Almoco EP 3505

About
Glass-fibre reinforced epoxy moulding compound Good mechanical strength, very good electrical isolation properties and dimensional stability even at high temperatures Primary application(s): Connectors, Thermocouples, Sensors, Resistors, Potentiometers This product meets the allowed upper limits for heavy metals and PCAs and also conforms to the requirements of the EU directives 2002/95 (RoHS), 2002/96 (WEEE) and 2006/122 (PFOS)&&

Product Description
Generic环氧树脂
Material StatusCommercial: Active
FeaturesGood Rigidity,Good Dimensional Stability,Good Electrical Properties,V-0
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.90 to 2.10g/cm³ISO 1183
Apparent density0.85 to 1.00g/cm³ISO 60
Shrinkage rate
MD0.30 to 0.50%ISO 2577
Water absorption rate
23℃,24hr< 0.10%ISO 62
Post contraction< 0.050%ISO 2577

MECHANICALNominal valueUnitTest method
Tensile modulus15000 to 18000MPaISO 527-2
tensile strength60.0 to 70.0MPaISO 527-2
Bending modulus14000 to 16000MPaISO 178
bending strength120 to 140MPaISO 178
compressive strength150 to 200MPaISO 604

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength2.5 to 3.5kJ/m²ISO 179-1eA
Charpy Unnotch Impact strength8.0 to 12kJ/m²ISO 179/1eU

THERMALNominal valueUnitTest method
Hot deformation temperature 
1.8 MPa, unannealed> 200ISO 75-2/A
8.0 MPa, unannealed170 to 190ISO 75-2/C
Linear coefficient of thermal expansion
MD:50~150℃1.5E-5 to 2.0E-51/℃ISO 11359-2
Thermal conductivity coefficient0.60 to 0.80W/m/KASTM E1461

Electrical performanceNominal valueUnitTest method
Surface resistivity1.0E+14 to 1.0E+15ohmsIEC 60093
Volume resistivity1.0E+15 to 1.0E+16ohms·cmIEC 60093
Dielectric strength25 to 35kV/mmIEC 60243-1
Relative permittivity IEC 60250
100 Hz5.00 7.00 IEC 60250
1 MHz4.00 6.00 IEC 60250
Dissipation factor IEC 60250
100 Hz0.010 to 0.030 IEC 60250
1 MHz0.010 to 0.030 IEC 60250
Arc resistancePLC 4 ASTM D495
Compared to the leakage tracing index> 250VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
5.00 mmV-0 UL 94
Glowing wire flammability index900IEC 60695-2-12
Igniting temperature of the hot wire900IEC 60695-2-13

Notes
1. Typical properties: these are not to be construed as specifications.
2. 168 h / 110°C
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.