VALOX™ V9561 resin

About
VALOX™   V9561 resin Flame retardant PET, 30% Glass fiber filled. Offering a good balance in CTI , GWIT , High Heat and mechanical performances.&&

Product Description
SupplierSABIC
GenericPET
Material StatusCommercial: Active
FeaturesFlame Characteristics,High Heat Resistance,V-0
AvailabilitysNorth America,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.72g/cm³ISO 1183
Melt Volume Rate
280℃,5 kg33.0cm³/10minISO 1133
Water absorption rate
Saturation, 23 ℃0.050%ISO 62
Equilibrium, 23 ℃, 50% RH0.25%ISO 62

MECHANICALNominal valueUnitTest method
Tensile modulus12000MPaISO 527-1-2
tensile strength
fracture125MPaISO 527-2/5
yield125MPaISO 527-2/5
Tensile strain
fracture2.0%ISO 527-2/5
yield2.0%ISO 527-2/5
Bending modulus10800MPaISO 178
bending strength190MPaISO 178

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength
23℃7.0kJ/m²ISO 179/1eA
Impact strength of cantilever beam notch ISO 180/1A
-30℃7.0kJ/m²ISO 180-1A
23℃7.0kJ/m²ISO 180-1A

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed, 64 mm span230ISO 75-2/Af
Vicat Softening Temp 
B50225ISO 306
B120230ISO 306/B120
Linear coefficient of thermal expansion
TD:23~80℃6.7E-51/℃ISO 11359-2
MD:23~80℃1.9E-51/℃ISO 11359-2

FLAME CHARACTERISTICSNominal valueUnitTest method
0.80 mmV-0 UL 94

Process Conditions
injectionNominal valueUnitTest method
Drying temperature120 to 130°C
Drying time4.0 to 6.0hr
Recommended maximum moisture content0.020%
Hopper temperature40 to 60°C
Barrel rear temperature250 to 270°C
Barrel middle temperature260 to 280°C
Barrel front temperature270 to 290°C
Nozzle temperature260 to 280°C
Processing (melt) temperature270 to 290°C
Mold temperature90 to 120°C

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.